Test Data AC2-09: Difference between revisions
m (Dave.Ellacott moved page SilverP:Test Data AC2-09 to Test Data AC2-09) |
|||
(50 intermediate revisions by the same user not shown) | |||
Line 28: | Line 28: | ||
{|align="center" border="1" width="700" | {|align="center" border="1" width="700" | ||
|+ align="bottom"|<b>Table EXP | |+ align="bottom"|<b>Table EXP – A </b>Summary description of all test cases | ||
!align="center"|Name | !align="center"|Name | ||
!align="center"|GNDPs | !align="center"|GNDPs | ||
Line 88: | Line 88: | ||
{|align="center" border="1" width="700" | {|align="center" border="1" width="700" | ||
|+ align="bottom"|<b>Table EXP | |+ align="bottom"|<b>Table EXP – B </b>Summary description of all measured parameters | ||
!align="center"|MP1||align="center"|MP2||align="center"|MP3||align="center"|DOAPs or other miscellaneous data | !align="center"|MP1||align="center"|MP2||align="center"|MP3||align="center"|DOAPs or other miscellaneous data | ||
|- | |- | ||
|align="center"|''U'', ''V'', ''u'' | |align="center" valign="top"|''U'', ''V'', ''u'' ′, ''v'' ′ (ms<sup>-1</sup>) | ||
|align="center" valign="top"|''η'', ''T'', ''η'' ′, ''T'' ′ (m<sup>2</sup>s<sup>-2</sup>) | |||
|align="center"|''Y''<sub>N<sub>2</sub></sub>, RMS(''Y''<sub>N<sub>2</sub></sub>) | |||
''Y''<sub>O<sub>2</sub></sub>, RMS(''Y''<sub>O<sub>2</sub></sub>) | |||
''Y''<sub>H<sub>2</sub>O</sub>, RMS(''Y''<sub>H<sub>2</sub>O</sub> ) | |||
''Y''<sub>H<sub>2</sub></sub>, RMS(''Y''<sub>H<sub>2</sub></sub>) | |||
''Y''<sub>CH<sub>4</sub></sub>, RMS(''Y''<sub>CH<sub>4</sub></sub>) | |||
''Y''<sub>CO</sub>, RMS(''Y''<sub>CO</sub> ) | |||
''Y''<sub>CO<sub>2</sub></sub>, RMS(''Y''<sub>CO<sub>2</sub></sub>) | |||
''Y''<sub>OH</sub>, RMS(''Y''<sub>OH</sub> ) | |||
''Y''<sub>NO</sub>, RMS(''Y''<sub>NO</sub> ) | |||
|} | |} | ||
==TEST CASE EXP1== | ==TEST CASE EXP1== | ||
Line 111: | Line 130: | ||
|[[Image:AC2-09_fig3b.gif|350px]] | |[[Image:AC2-09_fig3b.gif|350px]] | ||
|- | |- | ||
|colspan="3" align="center"|Fig. 3 | |colspan="3" align="center"|'''Fig. 3:''' Mean and RMS inlet profiles of the axial velocity. | ||
|} | |} | ||
Line 125: | Line 144: | ||
===Measured Data=== | ===Measured Data=== | ||
The velocity data (in ASCII format) can be obtained by contacting Prof. Andreas Dreizler, | |||
TU Darmstadt (dreizler@csi.tu-darmstadt.de). | |||
The scalar data are available at http://www.sandia.gov/TNF/DataArch/FlameD.html | |||
===References=== | ===References=== | ||
<references/> | <references/> | ||
Line 131: | Line 154: | ||
---- | ---- | ||
{{ACContribs | {{ACContribs | ||
|authors=Andrzej Boguslawski | |authors=Andrzej Boguslawski, Artur Tyliszczak | ||
|organisation= | |organisation=Częstochowa University of Technology | ||
}} | }} | ||
{{ACHeader | {{ACHeader | ||
Line 140: | Line 163: | ||
© copyright ERCOFTAC | © copyright ERCOFTAC 2011 |
Latest revision as of 15:42, 11 February 2017
SANDIA Flame D
Application Challenge AC2-09 © copyright ERCOFTAC 2024
Overview of Tests
The velocity measurements were performed with two-component fiber-optic laser Doppler anemometer (Dantec). All the details of the flow field measuring techniques applied in Sandia Flame D experiment are explained in[1]. Measured scalars for Sandia D Flame include temperature, mixture fraction, N2, O2, H2O, H2, CH4, CO, CO2, OH and NO. Experimental methods and measurement uncertainties are outlined in[1] Spontaneous Raman scattering of the beams from two Nd:YAG lasers (532 nm) was used to measure concentrations of the major species. The Rayleigh scattering signal was converted to temperature using a species-weighted scattering cross section, based on the Raman measurements. Linear laser-induced fluorescence (LIF) was used to measure OH and NO, and the fluorescence signals were corrected on a shot-to-shot basis for variations in Boltzmann fraction and collisional quenching rate. The concentration of CO was measured by Raman scattering and by two-photon laser-induced fluorescence (TPLIF).
Name | GNDPs | PDPs (Problem Definition Parameters) | MPs (Measured Parameters) | ||
---|---|---|---|---|---|
Re | Fuel jet composition | Pilot flame composition | Detailed data | DOAPs | |
EXP1 | 22400 | 25% of methane (CH4) and 75% of air | C2H2, H2, air, CO2 and N2 |
|
Axial profiles
Tmax , z/D (Tmax ) Lconst(η , YCH4 , YO2) Lconst(YH2O , YCO2) YH2, max , z/D (YH2, max ) YCO, max , z/D (YCO, max ) RMSmax z/D (RMSmax ) Radial profiles x/D = 15, 30, 45 Fmax , Umax r½(η) , r½(U ) |
MP1 | MP2 | MP3 | DOAPs or other miscellaneous data |
---|---|---|---|
U, V, u ′, v ′ (ms-1) | η, T, η ′, T ′ (m2s-2) | YN2, RMS(YN2)
YO2, RMS(YO2) YH2O, RMS(YH2O ) YH2, RMS(YH2) YCH4, RMS(YCH4) YCO, RMS(YCO ) YCO2, RMS(YCO2) YOH, RMS(YOH ) YNO, RMS(YNO ) |
TEST CASE EXP1
Description of Experiment
The Application Challenge includes just one test case, Sandia Flame D with defined Reynolds number of the fuel jet and the fuel and pilot flame compositions as given in Table EXP-A.
Boundary Data
The inlet mean and fluctuating velocity at the distance x/D=1 from the burner are shown in Fig.3. The inlet parabolic profile had a maximum at the centre of the fuel nozzle of Umax = 62 m/s. The pilot flame bulk velocity Upilot = 11.4 m/s and the coflow velocity Ucfl = 0.9 m/s.
Fig. 3: Mean and RMS inlet profiles of the axial velocity. |
Measurement Errors
The flow field measurement statistical errors are estimated in[1] as below 5% for the mean velocities and within 10% for fluctuating components. The scalar measurement errors are estimated and analyzed in[2]. The relative uncertainty (not including statistical noise or potential effects of spatial averaging) is estimated to be within 2% for the Raman measurements, 5% for OH, 5% for CO, and 10% for NO.
Measured Data
The velocity data (in ASCII format) can be obtained by contacting Prof. Andreas Dreizler, TU Darmstadt (dreizler@csi.tu-darmstadt.de).
The scalar data are available at http://www.sandia.gov/TNF/DataArch/FlameD.html
References
Contributed by: Andrzej Boguslawski, Artur Tyliszczak — Częstochowa University of Technology
© copyright ERCOFTAC 2011