== Comparison of CFD Calculations with Experiments ==
== Comparison of CFD Calculations with Experiments ==
For both "weak" and "strong" Mach number cases,for comparison with the calculations,
For both "weak" and "strong" Mach number cases,for comparison with the calculations,
experimental data for four measurements stations after the shock-wave (h1,h2,h3,h4) are
experimental data for four measurements stations after the shock-wave (h<sub>1</sub>, h<sub>2</sub>, h<sub>3</sub>, h<sub>4</sub>) are
selected for the longitudinal velocity as well as pressure distributions along the bottom
selected for the longitudinal velocity as well as pressure distributions along the bottom
and the top wall of the diffuser.
and the top wall of the diffuser.
Line 18: Line 18:
in fig.9.The x-location of the axial measurement stations are non-dimensionalized with the
in fig.9.The x-location of the axial measurement stations are non-dimensionalized with the
diffuser throat height,resulting in the following four stations:
diffuser throat height,resulting in the following four stations:
h1= 2.822,h2= 4.611,h3= 6.340 and h4= 7.493.
h<sub>1</sub>&nbsp;=&nbsp;2.822, h<sub>2</sub>&nbsp;=&nbsp;4.611, h<sub>3</sub>&nbsp;=&nbsp;6.340 and h<sub>4</sub>&nbsp;=&nbsp;7.493.
   
   
Figure 9.Shock-waves positions and experimental measurements  
Figure 9.Shock-waves positions and experimental measurements  

Revision as of 12:20, 12 April 2016

Converging-diverging transonic diffuser

Front Page

Description

Test Case Studies

Evaluation

Best Practice Advice

References

Confined flows

Underlying Flow Regime 4-19

Evaluation

Comparison of CFD Calculations with Experiments

For both "weak" and "strong" Mach number cases,for comparison with the calculations, experimental data for four measurements stations after the shock-wave (h1, h2, h3, h4) are selected for the longitudinal velocity as well as pressure distributions along the bottom and the top wall of the diffuser. A representative figure of the shock-wave positions and the measurement stations is shown in fig.9.The x-location of the axial measurement stations are non-dimensionalized with the diffuser throat height,resulting in the following four stations: h1 = 2.822, h2 = 4.611, h3 = 6.340 and h4 = 7.493.

Figure 9.Shock-waves positions and experimental measurements





Contributed by: Z. Vlahostergios, K. Yakinthos — Aristotle University of Thessaloniki, Greece