Comparison of Test Data and CFD

A rather good agreement between the experiments and predictions was obtained for gas and particle phase in both swirling cases considered. The comparison of the calculated streamlines of the gas flow with those obtained from the integration of the measured axial velocity shows that the flow field is predicted reasonably well for both conditions (Figure 10). The most obvious difference is that the axial extension of the central recirculation bubble is predicted to be larger at the top and downstream ends for both cases. The predicted width of the central recirculation bubble and the extension of the recirculation at the edge of the pipe expansion are in good agreement with the measured results.




Contributed by: Martin Sommerfeld — Martin-Luther-Universitat Halle-Wittenberg