Description AC6-07: Difference between revisions
No edit summary |
|||
(29 intermediate revisions by 3 users not shown) | |||
Line 1: | Line 1: | ||
{{AC|front=AC 6-07|description= | {{AC|front=AC 6-07|description=Description_AC6-07|testdata=Test_Case_AC6-07|cfdsimulations=AC 6-07 CFD Simulations|evaluation=AC 6-07 Evaluation|qualityreview=AC 6-07 Quality Review|bestpractice=AC 6-07 Best Practice Advice|relatedUFRs=AC 6-07 Related ACs}} | ||
='''Draft tube'''= | ='''Draft tube'''= | ||
Line 33: | Line 33: | ||
The main assessment parameters ([[DOAPs]]) for this AC are | The main assessment parameters ([[DOAPs]]) for this AC are | ||
• Pressure recovery factor | • Pressure recovery factor ''Cp''<sub>r</sub> | ||
• Energy loss coefficient | • Energy loss coefficient ''ζ'' | ||
• Kinetic energy correction factors | • Kinetic energy correction factors ''α''<sub>axial</sub> and ''α''<sub>swirl</sub> | ||
• Momentum correction factor | • Momentum correction factor ''β'' | ||
• Swirl intensity S | • Swirl intensity ''S'' | ||
The by far most important single assessment parameter is the pressure recovery factor. | The by far most important single assessment parameter is the pressure recovery factor. | ||
Line 91: | Line 91: | ||
where a lower value means higher efficiency for the draft tube. Index 1 refers to cross section Ia (Fig. 1.3 and 1.4) and index 2 refers to cross section IVb (Fig. 1.3 and 1.4). This coefficient is directly coupled to the losses in the system but is seldom used in experimental work since it requires knowledge about the variables over the whole inlet and outlet cross section. However, in CFD it is easily calculated. | where a lower value means higher efficiency for the draft tube. Index 1 refers to cross section Ia (Fig. 1.3 and 1.4) and index 2 refers to cross section IVb (Fig. 1.3 and 1.4). This coefficient is directly coupled to the losses in the system but is seldom used in experimental work since it requires knowledge about the variables over the whole inlet and outlet cross section. However, in CFD it is easily calculated. | ||
• '''Kinetic energy correction factors | • '''Kinetic energy correction factors α<sub>axial</sub> and α<sub>swirl</sub>''' | ||
at cross section Ia and cross section III : | at cross section Ia and cross section III : | ||
Line 106: | Line 106: | ||
True Kinetic energy flux = < | True Kinetic energy flux = ''α''<sub>axial</sub> + ''α''<sub>swirl</sub> | ||
(Kinetic energy flux computed using mean velocity) | (Kinetic energy flux computed using mean velocity) | ||
True specific kinetic energy: <math>e_{kin} = \frac{1}{2A\overline{u}_{ | True specific kinetic energy: <math>e_\text{kin} = \frac{1}{2A\overline{u}_\text{ax}} \left(\int\limits_A u^2 u_\text{ax} dA\right) = \frac{1}{2A\overline{u}_\text{ax}} \left(\int\limits_A u^3_\text{ax} dA + \int\limits_A u^2_{tang} u_\text{ax} dA\right)</math> | ||
Specific kinetic energy is computed using mean velocity: <math> | Specific kinetic energy is computed using mean velocity: <math>\overline{e}_\text{kin} = \frac{\overline{u}^2_\text{ax}}{2}</math> | ||
where A is the cross section area, u is the local magnitude of the total velocity vector, <math>\overline{u}_{ | where ''A'' is the cross section area, ''u'' is the local magnitude | ||
of the total velocity vector, <math>\overline{u}_\text{ax}</math> is the mean axial velocity perpendicular to the cross section = ''Q/A'', | |||
''u''<sub>ax</sub> is the local axial velocity and | |||
''u''<sub>tang</sub> is the local tangential velocity. | |||
• '''Momentum correction factor | • '''Momentum correction factor β which is defined as ''': | ||
<math> | <center><math> | ||
\beta = \frac{\text{True momentum flux}}{\text{Momentum flux computed using mean velocity}} = \frac{1}{A\overline{u}^2_\text{ax}} \int\limits_A u^2 dA | |||
\qquad\qquad(6) | |||
</math></center> | |||
where u is the local velocity, is the mean axial velocity and A is the cross sectional area. | where ''u'' is the local velocity, | ||
<math>\overline{u}_\text{ax}</math> is the mean axial velocity and | |||
''A'' is the cross sectional area. | |||
All of | All of ''α''<sub>axial</sub>, ''α''<sub>swirl</sub> and ''β'' | ||
characterise the nonuniformity of the velocity profile. | |||
• '''Swirl intensity S''' at cross section Ia and cross section III: | • '''Swirl intensity S''' at cross section Ia and cross section III: | ||
where | <center><math> | ||
S = \frac{\int\limits_A \left[u_\text{tang}r {(\rho u_\text{ax})}\right] dA} | |||
{\rho\int\limits_A u^2_\text{ax} dA} = \frac{1}{R}\frac{\int\limits^{r_0+R}_{r_0} u_\text{ax} u_\text{tang} r^2 dr}{\int\limits^{r_0+R}_{r_0} u^2_\text{ax} r dr} = | |||
\frac{\text{angle momentum flux}}{R \cdot \text{axial momentum flux}} | |||
\qquad(7) | |||
</math></center> | |||
where ''u''<sub>ax</sub> is the axial velocity, ''u''<sub>tang</sub> the | |||
tangential velocity, ''r<sub>0</sub>'' the inner radius | |||
and ''r<sub>0</sub> + R'' the outer radius (see Fig. 1.5). | |||
Still another pressure coefficient can be defined as | Still another pressure coefficient can be defined as | ||
in terms of which the loss coefficient, | <center><math> | ||
{C^\prime}_p = \frac{\int\limits_{A2} pu_\text{ax} dA - \int\limits_{A1} pu_\text{ax} dA}{\frac{1}{2}\rho\left(\frac{Q}{A_1}\right)^2 Q} | |||
\qquad\qquad\qquad\quad(8) | |||
</math></center> | |||
in terms of which the loss coefficient, ''ζ'', can be written as | |||
<math> | <center><math> | ||
\zeta = 1- \frac{\alpha_2}{\alpha_1} \left(\frac{A_1}{A_2}\right)^2 - | |||
\frac{{C^\prime}_p}{\alpha_1}\qquad\qquad\qquad\qquad(9) | |||
</math></center> | |||
where | where ''α<sub>1</sub>'' and ''α<sub>2</sub>'' are the sum of the swirl | ||
components at inlet and outlet, respectively. Since the last term in this expression is close to unity, the evaluation of ''ζ'' is ill-conditioned, a fact that will be discussed in some detail when assessing the accuracy of ''ζ''. | |||
=='''Flow Domain Geometry'''== | =='''Flow Domain Geometry'''== | ||
The flow geometry associated with the AC is specified below. The geometry is also available in different CAD-formats at [[http://www.sirius.luth.se/strl/Turbine-99/index.htm http://www.sirius.luth.se/strl/Turbine-99/index.htm]]. At the project home page some additional geometric information and a link to a ‘start’ grid that can be used for a grid-independent check of the CFD-numerics. | The flow geometry associated with the AC is specified below. The geometry is also available in different CAD-formats at | ||
[http://epubl.luth.se/1402-1536/2000/11/index-en.html http://epubl.luth.se/1402-1536/2000/11/index-en.html]. | |||
<!-- | |||
[[http://www.sirius.luth.se/strl/Turbine-99/index.htm http://www.sirius.luth.se/strl/Turbine-99/index.htm]] | |||
(bad link, DCE 10-03-10). At the project home page some additional geometric information and a link to a ‘start’ grid that can be used for a grid-independent check of the CFD-numerics.--> | |||
Figure 1.2 is a drawing of the entire draft tube. In Figure 1.3 one can see a sketch of available measurements at different cross sections, and in Figure 1.4 and Figure 1.5 exact locations for measurements for each cross section are given. Figure 1.6 defines the co-ordinate system used. Figure 1.7 shows the location of the upper and lower centre lines of the draft tube. | Figure 1.2 is a drawing of the entire draft tube. In Figure 1.3 one can see a sketch of available measurements at different cross sections, and in Figure 1.4 and Figure 1.5 exact locations for measurements for each cross section are given. Figure 1.6 defines the co-ordinate system used. Figure 1.7 shows the location of the upper and lower centre lines of the draft tube. | ||
Line 183: | Line 216: | ||
Figure 1.7. Upper and lower (wall) centreline. | Figure 1.7. Upper and lower (wall) centreline. | ||
=='''Flow Physics and Fluid Dynamics Data'''== | =='''Flow Physics and Fluid Dynamics Data'''== | ||
Line 218: | Line 250: | ||
Top Next | Top Next | ||
{{AC|front=AC 6-07|description= | {{AC|front=AC 6-07|description=Description_AC6-07|testdata=Test_Case_AC6-07|cfdsimulations=AC 6-07 CFD Simulations|evaluation=AC 6-07 Evaluation|qualityreview=AC 6-07 Quality Review|bestpractice=AC 6-07 Best Practice Advice|relatedUFRs=AC 6-07 Related ACs}} | ||
Latest revision as of 09:53, 3 May 2018
Draft tube
Application Challenge 6-07 © copyright ERCOFTAC 2004
Introduction
An experimental study has been performed of the flow in a sharp-heel draft tube for a Kaplan turbine. The measurements were made at the Turbine Testing Facility at Vattenfall Utveckling AB in Älvkarleby, Sweden. The draft tube is the curved diffuser downstream of the runner in a water turbine, and the purpose of the draft tube is to recover as much as possible of the kinetic energy of the flow after the runner. The efficiency loss in the draft tube is particularly important for low-head, high flow Kaplan power stations. The complete model consists of a 1:11 scale copy of the power station Hölleforsen including the rotating Kaplan runner, which has a diameter of 0.5 m. Figure 1.1 shows the draft tube. The Reynolds number ReD, based on runner diameter and average velocity is 1 750 000.
Figure 1.1. Schematic of Draft Tube Application Challenge.
Relevance to Industrial Sector
The flow in fluid machinery often involves the application of diffusers to convert kinetic energy in the fluid into pressure rise. A detailed understanding of the physics of the flow in such diffusers is of fundamental importance in order to improve the efficiency of the diffuser. The pressure recovery in a draft tube, which is the curved diffuser downstream of the runner in a water turbine, takes place in a very complicated geometry, which is determined by economic considerations regarding construction as well as fluid-mechanical considerations. Building costs are balanced against diffuser performance, and earlier designs (when building costs were relatively high) are optimised differently than modern designs. Whether the flow in the draft tube separates or not determines the ultimate pressure rise that can be achieved.
When refurbishing old hydro-power plants, there is therefore a potential for improving the pressure recovery in the draft tube by modifying the geometry of the draft tube. In order to utilise this potential, validated CFD tools are necessary.
The flow downstream of the runner in a water turbine, which is the inlet flow to the draft tube, is complicated with both a swirling mean flow, a periodic velocity component, and turbulence. The flow in the draft tube itself is composed by several co-existing flow phenomena or flow regimes: boundary layers in positive pressure gradient, flow curvature, flow rotation, and possibly (2- or 3-D) flow separation, thus creating a real application challenge. The test case put forward here is designed to test the ability of CFD codes to predict the pressure rise and flow field for such problems.
Design or Assessment Parameters
The main assessment parameters (DOAPs) for this AC are
• Pressure recovery factor Cpr
• Energy loss coefficient ζ
• Kinetic energy correction factors αaxial and αswirl
• Momentum correction factor β
• Swirl intensity S
The by far most important single assessment parameter is the pressure recovery factor.
Details of how to calculate each one of these are described below.
• Pressure recovery factor
The pressure recovery factor is defined as:
where Pout:wall is the outlet averaged static wall pressure at cross section IVb (Fig. 1.3 and 1.4), Pin:wall is the inlet averaged static wall pressure at cross section Ia (Fig. 1.3 and 1.4), r is the density, Q is the flow rate (m3/s) and Ain is the area at cross section Ia (Fig. 1.3 and 1.4). Observe that Ain does not include the runner cone in the centre of the inlet.
The inlet averaged static wall pressure, Pin:wall, has bean found very sensitive to the inlet conditions and the geometry at the inlet. Therefore, an alternative Cpr average
has also been used in the evaluation of the results, where Pout:mean and Pin:mean are the averaged static pressures across these sections. Note: Pout:mean for the experiments is estimated with Pout:wall, since the pressure has only been determined at the wall at the outlet section.
Cpr average is a direct result of the whole field solution for all variables (if the pressure is set at the outlet) and much less sensitive to different changes at the inlet. Unfortunately it is more difficult to determine experimentally, resulting in larger uncertainty.
The pressure recovery factor indicates the degree of conversion of kinetic energy into static pressure where a higher value means higher efficiency for the draft tube. The exact value of the pressure recovery factor depends on the whole field solution and can be seen as an integral property of the solution.
• Energy loss coefficient
where a lower value means higher efficiency for the draft tube. Index 1 refers to cross section Ia (Fig. 1.3 and 1.4) and index 2 refers to cross section IVb (Fig. 1.3 and 1.4). This coefficient is directly coupled to the losses in the system but is seldom used in experimental work since it requires knowledge about the variables over the whole inlet and outlet cross section. However, in CFD it is easily calculated.
• Kinetic energy correction factors αaxial and αswirl at cross section Ia and cross section III :
True Kinetic energy flux = αaxial + αswirl
(Kinetic energy flux computed using mean velocity)
True specific kinetic energy:
Specific kinetic energy is computed using mean velocity:
where A is the cross section area, u is the local magnitude of the total velocity vector, is the mean axial velocity perpendicular to the cross section = Q/A, uax is the local axial velocity and utang is the local tangential velocity.
• Momentum correction factor β which is defined as :
where u is the local velocity,
is the mean axial velocity and
A is the cross sectional area.
All of αaxial, αswirl and β characterise the nonuniformity of the velocity profile.
• Swirl intensity S at cross section Ia and cross section III:
where uax is the axial velocity, utang the tangential velocity, r0 the inner radius and r0 + R the outer radius (see Fig. 1.5).
Still another pressure coefficient can be defined as
in terms of which the loss coefficient, ζ, can be written as
where α1 and α2 are the sum of the swirl components at inlet and outlet, respectively. Since the last term in this expression is close to unity, the evaluation of ζ is ill-conditioned, a fact that will be discussed in some detail when assessing the accuracy of ζ.
Flow Domain Geometry
The flow geometry associated with the AC is specified below. The geometry is also available in different CAD-formats at http://epubl.luth.se/1402-1536/2000/11/index-en.html.
Figure 1.2 is a drawing of the entire draft tube. In Figure 1.3 one can see a sketch of available measurements at different cross sections, and in Figure 1.4 and Figure 1.5 exact locations for measurements for each cross section are given. Figure 1.6 defines the co-ordinate system used. Figure 1.7 shows the location of the upper and lower centre lines of the draft tube.
Figure 1.2. A definition of the draft tube geometry. (Complete information is available in the CAD-file).
Figure 1.3. Describes LDV and pressure experimental cross sections. This figure also shows the visualisation areas.
Figure 1.4. Describes exact location of LDV and pressure experimental cross sections.
Figure 1.5. Side and top view of the inlet cone of the test draft tube.
Figure 1.6. Coordinate system.
Figure 1.7. Upper and lower (wall) centreline.
Flow Physics and Fluid Dynamics Data
The flow in the draft tube (AC) is turbulent, incompressible (with no heat transfer, chemical reactions etc). The fluid is water (at 15°C)
The governing parameters for the AC are:
Operational parameters for the test-rig:
N11 Unit runner speed ( DN/√H )
Q11 Unit flow ( Q/D2√H ) ,
resulting in the non-dimensional Reynolds number(s) for the flow in the AC:
ReH Reynolds number (√(2gH)D/n )
(ReQ Reynolds number ( (4Q/πD2)D/n ))
Here H is the total head, Q is the flow rate, D is the runner diameter and N is the runner speed.
© copyright ERCOFTAC 2004
Contributors: Rolf Karlsson - Vattenfall Utveckling AB