UFR 2-14 Test Case: Difference between revisions
Rapp.munchen (talk | contribs) |
m (Dave.Ellacott moved page SilverP:UFR 2-14 Test Case to UFR 2-14 Test Case) |
||
(8 intermediate revisions by 2 users not shown) | |||
Line 1: | Line 1: | ||
= Fluid-structure interaction in turbulent flow past cylinder/plate configuration II = | = Fluid-structure interaction in turbulent flow past cylinder/plate configuration II (Second swiveling mode) = | ||
{{UFRHeader | {{UFRHeader | ||
|area=2 | |area=2 | ||
Line 13: | Line 13: | ||
== Description of the geometrical model and the test section == | == Description of the geometrical model and the test section == | ||
FSI-PfS-2a consists of a flexible rubber plate with an attached steel weight clamped behind a fixed rigid non-rotating cylinder installed in a water channel (see Fig. 1). The experiments use the same set-up as applied in [http://qnet-ercoftac.cfms.org.uk/w/index.php/UFR_2-13 FSI-PfS-1a]. As a consequence all channel related parameters | FSI-PfS-2a consists of a flexible rubber plate with an attached steel weight clamped behind a fixed rigid non-rotating cylinder installed in a water channel (see Fig. 1). The experiments use the same set-up as applied in [http://qnet-ercoftac.cfms.org.uk/w/index.php/UFR_2-13 FSI-PfS-1a]. As a consequence all channel related parameters such as the test section geometry, the blocking ratio and the working conditions including the inflow profile remain the same as described in FSI-PfS-1a. The differences of the present investigation are related to the modified structure definition of FSI-PfS-2a. The deformable structure used in the experiment behind the cylinder has a slightly shorter length with <math>l_1 \operatorname{=} 0.050\,m ~ (l_1/D \approx 2.27)</math>. The attached steel weight has a length of <math>l_2 \operatorname{=} 0.010\,m ~ (l_2/D \approx 0.46)</math>. Consequently, the summation of <math>l_1</math> and <math>l_2</math> yields the length <math>l\operatorname{=} 0.060\,m</math> identical to the plate of FSI-PfS-1a. The whole structure including the rigid cylinder, the flexible plate and the steel weight has a width <math>w \operatorname{=} 0.177\,m ~ (w/D \approx 8.05)</math>. Again small gaps of about <math>1.5 \times 10^{-3}\,m</math> are present between the lateral sides of the structure and the lateral channel walls. In contrast to the rubber material applied in FSI-PfS-1a the rubber used in FSI-PfS-2a has an almost constant thickness <math>h \operatorname{=} 0.002\,m ~ (h/D \approx 0.09)</math>. All parameters of the geometrical configuration of the FSI-PfS-2a benchmark are summarized as follows: | ||
[[Image:qnet_FSI-PfS-2a_measures.png]] | [[Image:qnet_FSI-PfS-2a_measures.png]] | ||
Line 85: | Line 85: | ||
== Computational fluid dynamics (CFD) == | == Computational fluid dynamics (CFD) == | ||
See [http:// | See [http://qnet-ercoftac.cfms.org.uk/w/index.php/UFR_2-13_Test_Case#Computational_fluid_dynamics_.28CFD.29 description for UFR 2-13]. | ||
== Computational structural dynamics (CSD) == | == Computational structural dynamics (CSD) == | ||
See [http:// | See [http://qnet-ercoftac.cfms.org.uk/w/index.php/UFR_2-13_Test_Case#Computational_structural_dynamics_.28CSD.29 description for UFR 2-13]. | ||
== Coupling algorithm == | == Coupling algorithm == | ||
See [http:// | See [http://qnet-ercoftac.cfms.org.uk/w/index.php/UFR_2-13_Test_Case#Coupling_algorithm description for UFR 2-13]. | ||
== Numerical CFD Setup == | == Numerical CFD Setup == | ||
Preliminary tests were conducted for the geometrically similar FSI-PfS-1a test case to identify the appropriate CFD domain size (see [http:// | Preliminary tests were conducted for the geometrically similar FSI-PfS-1a test case to identify the appropriate CFD domain size (see [http://qnet-ercoftac.cfms.org.uk/w/index.php/UFR_2-13 FSI-PfS-1]). The outcome was that a consideration of a part of the whole test section combined with periodic boundary conditions on the lateral boundaries is sufficient to get reliable | ||
flow results. This configuration is denoted ''subset case''. The geometry of the current FSI-PfS-2a test case is similar to | flow results. This configuration is denoted ''subset case''. The geometry of the current FSI-PfS-2a test case is similar to | ||
FSI-PfS-1a. Owing to the rear mass in the present case avoiding three-dimensional deformations of the flexible structure, the | FSI-PfS-1a. Owing to the rear mass in the present case avoiding three-dimensional deformations of the flexible structure, the | ||
restriction to the subset case is even | restriction to the subset case is even more justified than for FSI-PfS-1a. Therefore, the subset case is directly applied here: The | ||
depth of the computational domain is not the entire test section width <math>W/D \approx 8.18</math>, but a subset of the total width equal to the | depth of the computational domain is not the entire test section width <math>W/D \approx 8.18</math>, but a subset of the total width equal to the | ||
entire length of the splitter plate <math>\left( l_1 + l_2 \right)/D \approx 2.73</math> yielding a quadratic plate. A block-structured grid is | entire length of the splitter plate <math>\left( l_1 + l_2 \right)/D \approx 2.73</math> yielding a quadratic plate. A block-structured grid is | ||
Line 181: | Line 181: | ||
is non-deformable. For this rigid configuration the turbulent flow is predicted until it reaches | is non-deformable. For this rigid configuration the turbulent flow is predicted until it reaches | ||
a quasi-periodic state. In this case the shell attached to the backside of the cylinder acts | a quasi-periodic state. In this case the shell attached to the backside of the cylinder acts | ||
like a splitter plate attenuating the generation of a von | like a splitter plate attenuating the generation of a von Karman vortex street behind the | ||
cylinder. Nevertheless, quasi-periodic vortex shedding is still observed with a Strouhal number | cylinder. Nevertheless, quasi-periodic vortex shedding is still observed with a Strouhal number | ||
of <math>\text{St}_\text{fixed} \approx 0.175 </math>. Then, the structure is released and the FSI simulation begins. | of <math>\text{St}_\text{fixed} \approx 0.175 </math>. Then, the structure is released and the FSI simulation begins. | ||
Line 213: | Line 213: | ||
For a full description of the phase averaging procedure we refer to the description provided for | For a full description of the phase averaging procedure we refer to the description provided for | ||
[http:// | [http://qnet-ercoftac.cfms.org.uk/w/index.php/UFR_2-13_Test_Case#Generation_of_Phase-resolved_Data UFR 2-13]. | ||
---- | ---- | ||
{{ACContribs | {{ACContribs |
Latest revision as of 12:13, 12 February 2017
Fluid-structure interaction in turbulent flow past cylinder/plate configuration II (Second swiveling mode)
Flows Around Bodies
Underlying Flow Regime 2-14
Test Case Study
Description of the geometrical model and the test section
FSI-PfS-2a consists of a flexible rubber plate with an attached steel weight clamped behind a fixed rigid non-rotating cylinder installed in a water channel (see Fig. 1). The experiments use the same set-up as applied in FSI-PfS-1a. As a consequence all channel related parameters such as the test section geometry, the blocking ratio and the working conditions including the inflow profile remain the same as described in FSI-PfS-1a. The differences of the present investigation are related to the modified structure definition of FSI-PfS-2a. The deformable structure used in the experiment behind the cylinder has a slightly shorter length with . The attached steel weight has a length of . Consequently, the summation of and yields the length identical to the plate of FSI-PfS-1a. The whole structure including the rigid cylinder, the flexible plate and the steel weight has a width . Again small gaps of about are present between the lateral sides of the structure and the lateral channel walls. In contrast to the rubber material applied in FSI-PfS-1a the rubber used in FSI-PfS-2a has an almost constant thickness . All parameters of the geometrical configuration of the FSI-PfS-2a benchmark are summarized as follows:
Fig. 1: Geometrical configuration of the FSI-PfS-2a benchmark.
Description of the water channel
Flow parameters
Several preliminary tests were performed to find the best working conditions in terms of maximum structure displacement, good reproducibility and measurable structure frequencies within the turbulent flow regime.
Figure 2 depicts the measured extrema of the structure displacement versus the inlet velocity and Fig. 3 gives the frequency and Strouhal number as a function of the inlet velocity. These data were achieved by measurements with the laser distance sensor explained in Section Laser distance sensor. The diagrams are the result of a measurement campaign in which the inflow velocity was consecutively increased from 0 to 2.4 m/s. At an inflow velocity of (same inflow velocity as in FSI-PfS-1a) the displacements are symmetrical, reasonably large and well reproducible. Based on the inflow velocity chosen and the cylinder diameter, the Reynolds number is equal to Re = 30,470.
Fig. 2: Experimental displacements of the structure extremity versus the inlet velocity.
Fig. 3: Experimental measurements of the frequency and the corresponding Strouhal number of the FSI phenomenon versus the inlet velocity.
Regarding the flow around the front cylinder, at this inflow velocity the flow is again in the sub-critical regime. That means the boundary layers are still laminar, but transition to turbulence takes place in the free shear layers evolving from the separated boundary layers behind the apex of the cylinder.
Material Parameters
The density of the rubber material is found to be for a thickness of the plate h = 0.002 m. This permits the accurate modeling of inertia effects of the structure and thus static and dynamic test cases can be used to calibrate the material constants (see Kalmbach and Breuer, 2013; De Nayer and Breuer, 2014). Again the St. Venant-Kirchhoff constitutive law is chosen as the simplest hyper-elastic material model. Similar to FSI-PfS-1a, there are only two parameters to be defined: the Young's modulus and the Poisson's ratio . In Kalmbach and Breuer (2013) the Young’s modulus of the rubber was determined based on a purely static test case to . In De Nayer and Breuer (2014) a purely dynamic test case was carried out and led to a slightly different value of . The Poisson's ratio of the rubber is . A detailed description of all structural tests is available in Kalmbach and Breuer (2013) and De Nayer and Breuer (2014). The properties of the steel weight are given in the table below.
Structural parameters (flexible structure: para-rubber):
Density | |
Young's modulus | |
Poisson's ratio |
Structural parameters (rear mass: steel):
Density | |
Young's modulus | |
Poisson's ratio |
Measuring Technique
Particle-image velocimetry
Laser distance sensor
Numerical Simulation Methodology
Computational fluid dynamics (CFD)
Computational structural dynamics (CSD)
Coupling algorithm
Numerical CFD Setup
Preliminary tests were conducted for the geometrically similar FSI-PfS-1a test case to identify the appropriate CFD domain size (see FSI-PfS-1). The outcome was that a consideration of a part of the whole test section combined with periodic boundary conditions on the lateral boundaries is sufficient to get reliable flow results. This configuration is denoted subset case. The geometry of the current FSI-PfS-2a test case is similar to FSI-PfS-1a. Owing to the rear mass in the present case avoiding three-dimensional deformations of the flexible structure, the restriction to the subset case is even more justified than for FSI-PfS-1a. Therefore, the subset case is directly applied here: The depth of the computational domain is not the entire test section width , but a subset of the total width equal to the entire length of the splitter plate yielding a quadratic plate. A block-structured grid is generated consisting of 91 blocks involving about 14 million control volumes (CVs). Note that this resolution is chosen based on the experiences made for the FSI-PfS-1a test case (de Nayer et al., 2014). Figure 4 shows the x-y cross-section of the grid. Since only every fourth grid line of the mesh is shown in Fig. 4, the angles between the grid lines and the transitions between the blocks appear to be worse than they are in the full grid. In order to fully resolve the viscous sublayer on the elastic structure, the first cell center is located at a distance of from the flexible structure, which leads to average values below 0.8, mostly even below 0.5 near the body. The geometrical stretching factors are kept below 1.1. In spanwise direction the grid consists of 72 equidistant cells. The inflow side is rounded in order to use a C-grid. Consequently, the computational domain in front of the cylinder is slightly larger than in the test section depicted in Fig. 1. On the right side a convective outlet boundary condition is applied. On the cylinder and on the flexible structure no-slip walls are defined. The top and the bottom of the domain are relatively far away from the flexible structure and are thus taken into account via slip walls. The lateral sides are assumed to be periodic as mentioned above.
The numerical method developed is based on an explicit time-marching scheme involving the low-storage Runge Kutta algorithm described above. Hence a small time step of is used. This time step size corresponds to a CFL number in the order of unity.
The subgrid-scale (SGS) model chosen for the main simulation is the Smagorinsky model (Smagorinsky, 1963). It is applied with the well established standard constant and a Van Driest damping function near solid walls. Owing to the moderate Reynolds number considered and the fine grid applied, the SGS model is expected to have a limited influence on the results. Nevertheless, in order to investigate and verify this issue, FSI simulations using the dynamic procedure as suggested by Germano et al. (1991) and Lilly (1992) and the WALE model by Nicoud and Ducros (1999) are carried out and analyzed in Section Sensitivity study. That includes a study on the model parameters and their influence on the results.
Fig. 4: x-y cross-section of the grid used for the simulation with 197,136 CVs (Note that only every fourth grid line in each direction is displayed here).
Numerical CSD Setup
The thin flexible structure and the rear mass are modeled by quadrilateral four-nodes shell elements. These elements are special seven-parameters shell elements (Bischoff, 1999). Preliminary structural tests show that shell elements for the flexible para-rubber and shell elements for the stainless rear mass are sufficient to deliver accurate results. The well-known Assumed Natural Strain (ANS) (Hughes and Tezduyar (1981), Park and Stanley (1986)) is deactivated in the current case and the Enhanced Assumed Strain (EAS) method is set to (M,B,T,Q,S)=(4,0,4,4,0) avoiding locking phenomena as proposed by Bischoff et al. (2004).
The flexible structure is clamped to the cylinder: All the nodes at the shell edge in contact with the cylinder have zero degree of freedom (DoF). On the opposite downstream trailing-edge, the rear mass is free to move and all nodes have the full set of six degrees of freedom. The nodes on the lateral sides have to fit to the periodic CFD boundary conditions: The x-displacements, the y-displacements and the rotations have to be the same for a lateral node and its opposite counterpart. Moreover, the periodic boundary conditions imply that the z-displacement of the nodes on the sides are forced to be zero. This special treatment of the lateral nodes is explained in detail and validated in De Nayer et al. (2014) for the FSI-PfS-1a test case.
A FSI sub-cycling algorithm is not implemented. Therefore, the same time step as for the CFD solver is set.
Coupling conditions
In accordance with previous laminar and turbulent test cases in Breuer et al. (2012) and De Nayer et al. (2014) a linear extrapolation of the structural deformation is used at the beginning of any new time step to accelerate the convergence. A second-order extrapolation is not taken into account, since it was observed that it does not improve the convergence for the current small time step size. Furthermore, a constant underrelaxation factor of is considered for the displacements during the FSI-subiterations to stabilize the coupling. The forces are exchanged without underrelaxation. The FSI convergence criterion is set to for the norm of the displacement differences between two FSI-subiterations normalized by the displacement differences between the current and the old time step. With these settings about 5 FSI-subiterations are required to reach the convergence criterion.
For the sake of clarity, the whole computational setup is summarized below.
For the current FSI simulation the flow field is initialized by assuming that the entire structure
is non-deformable. For this rigid configuration the turbulent flow is predicted until it reaches
a quasi-periodic state. In this case the shell attached to the backside of the cylinder acts
like a splitter plate attenuating the generation of a von Karman vortex street behind the
cylinder. Nevertheless, quasi-periodic vortex shedding is still observed with a Strouhal number
of . Then, the structure is released and the FSI simulation begins.
A time interval of about 2 seconds physical time is computed. The structure requires a few cycles until a
statistically steady-state is reached. After that a phase-averaging is carried out.
Generation of Phase-resolved Data
The results obtained by the experiment and the simulation cannot be directly compared. Indeed, due to turbulence, the data contain a random chaotic part. This contribution has to be filtered out in order to obtain phase-averaged data which can be compared directly. A special procedure, called phase-averaging method, has been explained in detail in Kalmbach and Breuer (2013) to treat both, the experimental and the numerical data sets. For this procedure a representative signal of the FSI problem is needed. In the present case the deformations of the plate are quasi two-dimensional due to the rear mass. Therefore, the y-displacement of the flexible structure at the monitoring point close to the trailing edge is chosen for this purpose. The current FSI phenomenon is quasi-periodic. This quasi-periodicity can also be confirmed by looking at the predicted phase plane which shows a typical form of a ”8” for the second swiveling mode.
Each period found is divided into n equidistant sub-parts (here n = 23). The sub-part j of the period corresponds to the sub-part j of the period and so on. Each data set found in a sub-part j is averaged with the other data sets found in the sub-parts j of all other periods. Finally, data sets of n = 23 phase-averaged positions for the representative reference period are achieved. For the experiment, about 47 particle-image velocimetry (PIV) data sets are averaged for each of the 23 structure positions. For the simulation, about 40 numerical data sets are averaged for each of the 23 structure positions. Note that the numerical data sets are also averaged in spanwise direction, in order to get better phase-averaged mean values. That is the main reason why the phase-averaging procedure for the measurements comprises about 150 periods, whereas for the numerical results only 15 periods are taken into account.
For a full description of the phase averaging procedure we refer to the description provided for UFR 2-13.
Contributed by: Andreas Kalmbach, Guillaume De Nayer, Michael Breuer — Helmut-Schmidt Universität Hamburg
© copyright ERCOFTAC 2024